JCB — Pressure/Flow Regulator Valve

www.WorkshopManuals.co.uk Hydraulic Pump - Variable Flow Pressure/Flow Regulator Valve The pressure and flow regulator valve assembly is mounted to the pump. The valve maintains the pump pressure and flow rate in accordance with demand at the service valve blocks. Load Sensing - Stand-by Position Stand-by is when the machine is running but the control levers are in neutral position, i.e. no implements are being used. There is no pressure or flow demands on the pump, therefore there will be no pressure signal . With the engine switched off, spring 1 holds swashplate 2 at the maximum angle.

When the engine is started and the pump begins to turn, oil begins to flow and pressure builds in the closed centre hydraulic system. Valve 5 houses a flow regulator spool 4 and pressure regulator spool 3 . Pressure which is building in the closed centre system is sensed at port P of the regulator valve. The increasing pressure pushes flow compensating spool 4 up against its spring 6 . This movement creates a flow path from port P to port A . Oil now flows from the flow regulator valve (via port A ) to swashplate control piston 7 . The control piston now moves the swashplate 2 towards its minimum angle.

As the piston moves towards its full travel position, cross-drilled holes 8 are uncovered allowing oil to drain. 1 The cross-drilled holes limit the travel of the control piston - when the holes are exposed, pump flow is insufficient to make up for leakage through the holes and maintain the pressure behind the control piston. Therefore the piston moves back to partially cover the cross holes thus maintaining enough flow to cater for normal system leakage whilst establishing a system stand-by pressure (see Technical Data for pressure). A275760 9803/3280 Purchased from www.WorkshopManuals.co.uk Issue 1 Section E Hydraulics Section E 5 - 5 5 - 5 Circuit Descriptions P A T P A 7 2