JCB — Pressure/Flow Regulator Valve

www.WorkshopManuals.co.uk Hydraulic Pump - Variable Flow Pressure/Flow Regulator Valve Load Sensing - Maximum Flow When a service is operated, the signal pressure from the loader (or backhoe) valve 13 increases. The increase in signal pressure combined with the force of spring 6 moves spool 4 down. Oil in control piston 7 is allowed to drain back to the tank via restrictor 9 and passage 10 . The force of spring 1 is now sufficient to increase the angle of swashplate 2 . The increased angle of the swashplate increase the output of the pump.

The pump output pressure will continue to increase, eventually the pressure will move flow regulating spool 4 against the force of spring 6 and the signal pressure in cavity 11 . Pump output pressure is now sent to control piston 7 via port A . Control piston 7 will overcome the force of spring 1 . The pump swashplate angle decreases and therefore the pump outlet decreases. Eventually the pressure in the load sense line and the force of spring 6 will move spool 4 down and the ‘metering’ cycle starts again. The up and down movement of the spool 4 keeps the pressure on both ends of the spool equal.

Spring 6 is equivalent to 20 bar (290 lbf/in 2 ), therefore the pump pressure should be this amount greater than the signal pressure (except when at maximum pressure - see Load Sensing - Maximum Pressure (no flow) . 1 A275770 9803/3280 Purchased from www.WorkshopManuals.co.uk Issue 1 Section E Hydraulics Section E 5 - 7 5 - 7 Circuit Descriptions 6 P A T 6 P A 6 7 2