JCB — Shuttle Valve Signal Network

9803/3280 Purchased from www.WorkshopManuals.co.uk Issue 1 Hydraulics Section E 7 - 7 Circuit Descriptions 7 - 7 Loader Valve - Variable Flow Shuttle Valve Signal Network Each control valve section has two shuttle valves. Each valve compares two pressure signals. One of the shuttles is the primary 18 and the other is the secondary 17. The primary shuttle 18 compares the pressure signal between the two service ports A and B in each valve section, the head and the rod pressure of the cylinder. In the example shown the boom service 37 port B pressure signal is greater than port A. Primary shuttle 18 moves across, the pressure signal is the highest shuttle pressure.

This signal pressure passes to the next shuttle. The secondary shuttle operates the same as the primary shuttle but compares pressure signals between valve sections. The signal network is arranged in series. It starts at loader valve block 9 inlet section which is connected to the steer valve 45. The last secondary shuttle in the loader valve block is connected to the first secondary shuttle in the backhoe valve block 25. The highest shuttle signal pressure from the loader valve block goes to the backhoe valve block. The highest shuttle signal pressure is felt at the hydraulic pump which instructs the pump to vary the output to meet the highest shuttle load requirement.

The stand-by pressure spool in the pump adds margin pressure to the load requirement. The single highest shuttle signal pressure plus margin pressure governs pump output. The pump will not change output until the shuttle network identifies a different shuttle signal. A B 30 37 18 17 P LS T 9 LOADER VALVE 37 B 1 17 25 BACKH 45 STEER VALVE P PUMP A 8 OE VALVE A316510 A316510 30 18 17 1 17 8