JCB — Precision Control (Servo)

www.WorkshopManuals.co.uk 9803/3280 Purchased from www.WorkshopManuals.co.uk Issue 2* Section E Hydraulics Section E 8 - 16 8 - 16 Circuit Descriptions Excavator Valve Precision Control (Servo) (continued) (Machines up to serial no. 931159) Load Sense (Isolator Compensator) Valve Operation No service is selected (all spools in neutral) With the spools in the neutral position oil from the pump P flows to each spool and is dead ended. This generates sufficient pressure (about 20bar) to overcome the spring E1 and oil flows across the bypass compensator spool assembly E to tank. Note that oil from the pump also flows into the ‘auxiliary pump gallery’ 1.

Oil from the ‘bridge galleries’ 3 is vented to tank via a groove in the main spool S. * Any load on the service ram R is held by the main spool S. Oil is also vented to tank from the load sense gallery 2 via the load sense drain regulator/relief valve F (see below). Spool at point of operating a service Pressure from the load on ram R enters the bridge gallery 3 via the service port 4. Compensator check valve H is held down on its seat preventing the load moving. At the same time the isolator spool U lifts and allows oil from the auxiliary pump gallery 1 to flow into the load sense gallery 2.

Oil pressure builds in gallery 1 and the bypass compensator spool E begins to close under the action of the oil and spring (E1) pressure. This causes the pump pressure to rise to a new value as follows: Pump pressure = Pressure in load sense gallery 2 + pressure from spring E1. When the pressure in load sense gallery 2 reaches the load pressure, isolator spool U moves down and closes off the auxiliary pump gallery 1 from load sense gallery 2. If the load pressure subsequently rises or falls, the isolator spool moves due to pressure imbalance and maintains the pressure in the load sense gallery 2 at the same pressure as the load pressure.

The pressure in the load sense gallery 2 always bleeds to tank, again causing pressure imbalance and the isolator spool to move, allowing the pressure in the gallery to be ‘topped up’. This ensures that ‘pressure balance’ is always maintained. It must be noted that the load sense gallery 2 is connected to all load sense valves (one for each service). The pressure in the gallery 2 will always be equal to the highest load from any of the backhoe services. The maximum load sense pressure is regulated by the load sense drain regulator/relief valve F (see below). Spool fully operating a service As the spool S is moved further oil from the pump is diverted into the central gallery 5.

If the pump pressure has risen F sufficiently (to a pressure equal to the load + spring pressure E1) then check valve H moves up off its seat and allows oil to flow into bridge gallery 3, and out to the ram R via service port 4. Exhaust oil from the other side of ram R is diverted to tank. F F