JCB — Precision Control (Servo)

www.WorkshopManuals.co.uk Excavator Valve Precision Control (Servo) (continued) (Machines from January 2003) Load Sense - Pressure Compensator Valves Operation Operating an individual service It must be noted that the load sense gallery LS is connected to all the pressure compensator valves PC (one for each service) as shown. The pressure in the load sense gallery LS will always be equal to the highest load from any of the backhoe services. The pressure compensator valves are fitted between each service spool and service ram and sense the pressure acting on either side of the particular service spool.

The pressure compensator valve will move in response to the pressure drop (pressure differential) created across the spool. When one service only is operated the pressure compensator valve PC is FULLY opened as shown, connecting the gallery P1 to gallery P2 and to the ram service port without any pressure drop. Operating multiple services a) Normal Condition b) With insufficient flow from pump When another service with a higher load is operated simultaneously, a typical example is the lifting of the boom and simultaneous operation of the bucket as shown.

Should the oil flow demanded by the sum of the combined services operating ever exceed that of the pump, all the pressure compensator valves will partially close accordingly, effectively dividing the available flow between all the services proportionally. The higher load pressure in the boom service causes the pressure compensator valve PC in the bucket service to partially close, reducing the size of the opening through which the oil must flow, and in this way maintains a pressure drop across the pressure compensator equal to the pressure drop across the bucket service spool.

In this condition the service ram with the highest load will NOT stop, because the speed of the other service rams operating will have been reduced proportionaly by the action of the pressure compensator valves to compensate. In this example, because of the action of the pressure compensator valve the bucket service is always kept independant of the other services, the bucket ram speed remains constant (as controlled by the bucket service spool) and is not affected by the greater operating pressure in the boom service. When one of the service spools is returned to neutral, the speed of the other service rams still operating will all increase proportionally.

9803/3280 Purchased from www.WorkshopManuals.co.uk Issue 1 Section E Hydraulics Section E 8 - 22 8 - 22 Circuit Descriptions