9803/3280 Purchased from www.WorkshopManuals.co.uk Issue 1 Hydraulics Section E Section E 15 - 1 15 - 1 Fault Finding Hydraulic System - Fixed Flow Fault Finding Contents Page No. Introduction 15 - 1 Lack of power in all hydraulic functions 15 - 1 All hydraulic rams slow to operate 15 - 2 One hydraulic service fails to operate or is slow to operate 15 - 2 The engine tends to stall when the hydraulics are under load 15 - 2 A spool is sticking 15 - 3 Leaking Oil Seal (Control Valves) 15 - 3 Ram creep 15 - 3 Hydraulic oil becomes too hot 15 - 4 Introduction The purpose of this section is to help you trace hydraulic faults to a faulty unit (valve, actuator, ram etc).
Once you have traced the faulty unit, refer to the appropriate dismantling, inspecting and test instructions given elsewhere in the hydraulics section. To help identify circuits, valves, rams etc mentioned in the fault finding procedures, refer to the hydraulic schematic diagrams (near the beginning of the Hydraulics Section). 1 Before you begin fault finding, read the Safety information at the beginning of this manual. 2 Make simple checks before say, stripping a major component. 3 Make sure that the hydraulic fluid is at correct working temperature (50 °C, 122 °F). 4 What ever the fault, check the condition of the hydraulic fluid. Drain and replace if necessary.
5 Make any relevant electrical checks before moving on to the hydraulics. 6 Be sure to remove ALL contamination and if possible identify its origin. It may be part of a component from elsewhere in the circuit. 7 Replace any seals such as 'O' rings before re- assembling hydraulic components. Introduction The purpose of this section is to help you trace hydraulic faults to a faulty unit (valve, actuator, ram etc). Once you have traced the faulty unit, refer to the appropriate dismantling, inspecting and test instructions given elsewhere in the hydraulics section.
To help identify circuits, valves, rams etc mentioned in the fault finding procedures, refer to the hydraulic schematic diagrams (near the beginning of the Hydraulics Section). 1 Before you begin fault finding, read the Safety information at the beginning of this manual. 2 Make simple checks before say, stripping a major component. 3 Make sure that the hydraulic fluid is at correct working temperature (50 °C, 122 °F). 4 What ever the fault, check the condition of the hydraulic fluid. Drain and replace if necessary. 5 Make any relevant electrical checks before moving on to the hydraulics. 6 Be sure to remove ALL contamination and if possible identify its origin.
It may be part of a component from elsewhere in the circuit. 7 Replace any seals such as 'O' rings before re- assembling hydraulic components. Fault Probable Cause Action 1 Lack of power in all hydraulic functions. Insufficient hydraulic fluid. Hydraulic leaks in system. Engine performance. Main relief valve (MRV) setting incorrect. Low pump flow. Hydraulic tank breather Tank filter by-pass valve Unloader valve pressure setting too high Check for leaks and top up as required. Check hoses, replace as required. Check engine performance, see transmission section for stall speed test procedures. Check and adjust as required. Check pump flow, if required service or replace pump.
Clean or replace the breather Check condition of hydraulic filter Check pressure setting of the unloader valve. ..... continued