JCB — Fixed Flow

9803/3280 Purchased from www.WorkshopManuals.co.uk Issue 1 Hydraulics Section E Section E 15 - 3 15 - 3 Fault Finding Fault Probable Cause Action 5 A spool is sticking. Oil temperature abnormally high. The hydraulic fluid is dirty. The service pipe connection is over tightened. The valve housing was twisted during installation. Pressure too high. A control linkage is bent A spool is bent A return spring is broken. A return spring or cap is out of alignment. Temperature distribution within control valve not uniform. Check for correct fluid, see Lubricants and Capacities. Check oil cooler and grille for blockage. Clean the tank strainer.

If strainer badly clogged, drain and flush hydraulic system Fill with clean hydraulic fluid. Check tightening torque. Loosen retaining bolts and tighten to correct torque figures. Check system pressure. Disconnect the linkage. Repair the linkage if possible, or fit a new one Dismantle the control valve. Renew spool as necessary. Renew as necessary. Remove the cap, check that the spring is in the correct position. Refit cap and torque tighten bolts Warm the entire system up before using service. 6 Leaking Oil Seal (Control Valves) Paint or dirt on the seal face. The back pressure in the valve circuit is excessively high. Spool damaged. The seal is not secured. The seal is cut or damaged.

Remove the seal and clean. Check circuit pressures, adjust if possible. Otherwise investigate thoroughly. Dismantle. Inspect all parts. Renovate or renew as necessary. Clean the seal and tighten the retaining bolts to the correct torque. Fit a new seal. 7 Ram creep. Associated ram or pipe lines from Check and rectify as required. ram leaking. Check valve malfunctioning Test check valve, rectify as required. (if fitted, e.g. stabiliser circuit) Associated valve section spools Rectify, check for contamination. leaking. Associated ARV leaking Rectify, check for contamination . Note: Refer also to Service Procedures, Ram Creep Tests - All Services