www.WorkshopManuals.co.uk 9803/3280 Purchased from www.WorkshopManuals.co.uk Issue 2* Section E Hydraulics Section E 23 - 10 23 - 10 Service Procedures Excavator Valve - Precision Control (Servo (Machines up to serial no. 931159) Pressure Testing Load Sense Drain Regulator and Relief Valve Make sure that the hydraulic oil is at working temperatur i.e. 50°C (122°F). Lower the backhoe bucket and loader shovel to rest on th ground; stop the engine; operate the control levers to ven residual hydraulic pressure. 1 Connect a 0 - 400 bar (0 - 6000 lbf/in2) pressure gaug to pressure test connector A on the loader valve, (refe to Service Tools).
2 With the engine running at 1500 revs/min, check tha the M.R.V. pressure is correct, see Loader Valve Pressure Testing, Main Relief Valve. 3 With the engine running at 1500 revs/min, operate stabiliser service fully and at the same time note th reading in the gauge which should be as stated i Technical Data. Note: The ram must be 'held' open or closed when readin gauge. 4 If the pressure is incorrect, loosen locknut D and adju screw C. Turn the screw C clockwise to increas pressure and anti-clockwise to decrease the pressur When the pressure is correct, tighten the locknut an check the pressure again. Adjust as required. ) e, e t e r t - a e A n g st e e. d * C D