www.WorkshopManuals.co.uk Fixed Flow Dismantling and Assembly Before removing and dismantling the pump, check flow and pressure. If either of these are low the pump must be changed. Renewal of components such as gears, bearings and housing will not effect a permanent cure. If the pump output is satisfactory but there is external leakage, the pump should be removed and dismantled for re-sealing only. 12 Discard O-ring 31 . 13 Remove all sealant from the contact faces of the mounting flange/front body and end cover/rear body interfaces. 14 Wash all components and immediately apply a coating of hydraulic oil to prevent corrosion.
Before removing and dismantling the pump, make sure the exterior of the pump and working area is thoroughly cleaned and free of possible sources of contamination. Inspection Dismantling 1 Generally check all pump parts for damage and/or wear. The O-ring grooves, the seal recess in the mounting flange and all sealing faces must be free of burrs and scores which could result in seal damage and hence hydraulic oil leakage. 1 Remove the four bolts 3 and serrated washers 4 which clamp the units together. 2 Use a soft faced hammer to separate front body 5 and rear body 6 after first marking them to ensure correct re-assembly. 2 Renew the pump if any of the following symptoms exist:
3 Remove splined coupling 7 and O-rings 8 . Discard the O-rings. a The PTFE coated bearings in the pump bodies, the mounting flange and the end cover are worn through to reveal the bronze backing. 4 Use a soft faced hammer to separate end cover 9 from rear body 6 , after first marking them to ensure correct re-assembly. b The gear side faces are scored. Often contaminated fluid results in a distinct wear step coincident with the gear root diameter. This can normally be felt by drawing a sharp point across the gear side face from the journal towards the tip of the gear. 5 Remove drive gear 10 from its bore.
Pushing it out of the rear body will also remove balance plate 11 complete with seal 12 and seal energiser 13 . Discard the seal and seal energiser. Note the position of the driveshaft and the balance plate to ensure correct re- assembly. c There is a noticeable wear groove on driveshaft 23 where seals 22 run. d The balance plate faces are scored, particularly in the area adjacent to the gear root diameter. 6 Remove driven gear 14, followed by balance plate 15 complete with seal 16 and seal energiser 17 . Discard the seal and seal energiser. e The shaft splines are worn or severely fretted. 7 Discard O-ring 18.
f The gear "cut-in" area in the low pressure side of the pump body is deeper than 0.15 mm (0.006 in) or has a torn or pitted appearance. 8 Use a soft hammer to separate mounting flange 19 from front body 5 , after first marking them to ensure correct re-assembly. 9 Remove circlip 21 and shaft seals 22. Note which way round the seal lips are fitted to ensure correct fitting of new seals on re-assembly. 10 Remove driveshaft 23 from front body 5 . Removal will also remove balance plate 28 complete with seal 29 and seal energiser 30 . Discard the seal and seal energiser. 11 Remove driven gear 27 followed by balance plate 24 , seal 25 and seal energiser 26. Discard the seal and seal energiser.
9803/3280 Purchased from www.WorkshopManuals.co.uk Issue 1 Section E Hydraulics Section E 31 - 2 31 - 2 Main Pump