www.WorkshopManuals.co.uk Dismantling and Assembly Unloader Valve The numerical sequence shown on the illustration is intended as a guide to dismantling. Assembly Renew all 'O' rings and back-up rings. For assembly the sequence should be reversed. Lubricate parts with JCB Hydraulic Fluid before assembling. Make sure that all the parts move freely. The following points MUST be avoided when dismantling and assembling the valve: Ensure that the small drilling through the centre of items 23 , is clear. CONTAMINATION DAMAGE TO SPOOL DAMAGE TO SEAL GROOVES Shims 21 are intended to limit the maximum pressure setting, the specified pressure setting is achieved by adjusting capnut 15 .
If the specified pressure cannot be achieved under test, it is permissible to add shims as required. There MUST be at least one hardened shim next to the spring item 22 . All or any of the above points may result in possible problems with the valve. Dismantling When removing 'O' rings and seals, use an an appropriately rounded tool that WILL NOT cause any damage to the seal grooves. Do not over-tighten the solenoid assembly, it may effect the operation of the solenoid, use the spanner flats and torque tighten to figure indicated in the table below (items 1 and 5 ). Fit chamfered end of spring 22 against head of pilot poppet item 23 . Discard ALL 'O' rings and back up rings.
DO NOT use worn or damaged items. Use a nylon rod to push out spool assembly item 23 , DO NOT damage spool bore. Check pressure setting after refitting, refer to Service Procedures, Loader Valve - Pressure Testing . Check the operation of the hydraulic speed control, refer to Service Procedures, Loader Valve - Pressure Testing . Inspect the valve components for scratches, nicks or any other type of damage, replace with new if required. Torque Settings Item Nm kgf m lbf ft 1 6.7 0.7 5 5 27 2.8 20 8 81 8.3 60 12 81 8.3 60 16 45 4.6 33 19 34 3.5 25 9803/3280 Purchased from www.WorkshopManuals.co.uk Issue 1 Section E Hydraulics Section E 50 - 11 50 - 11 50 - 11 Loader Valve - Fixed Flow 50 - 11