www.WorkshopManuals.co.uk Dismantling and Assembly Electric Detent Spool - Manual The numerical sequence shown on the illustration is intended as a guide to dismantling. Assembly For assembly the sequence should be reversed. 1 Fit the boot 1A to the seal plate 2 . The following points MUST be avoided when dismantling and assembling the valve: 2 Fit a new lipseal 4 into the valve block, ensure square. Fit wiper 3 on top of lipseal. 3 Fit the seal plate and boot assembly to valve block but do not torque tighten capscrews 1 at this stage. Ensure wiper locates into seal plate. CONTAMINATION DAMAGE TO SPOOL DAMAGE TO SEAL GROOVES 4 Use clean hydraulic oil as a lubricant.
From the bottom, insert spool through the valve block, do not use excessive force when fitting, a turning motion should ease the spool through the valve block. All or any of the above points may result in possible problems with the valve. Dismantling When removing 'O' rings and seals, use an appropriately rounded tool that WILL NOT cause any damage to the spool or seal grooves, for instance, item 3 , which is a wiper seal and is a press fit in the counterbore. 5 Check that the tang end of the spool passes through the boot without dislodging or damaging the boot. Ensure that the tang aligns with the control rod and that the boot is not distorted and is located in the spool land.
Care must be taken to ensure that the spool 12 is not damaged when removing it from the valve block. 6 Torque tighten cap screws 1 . 7 When fitting spool end 15 , clean the threads thoroughly using JCB Cleaner/Degreaser, leave it for 10 minutes then apply a small quantity of JCB Threadlocker and Sealer to the threads of the spool. Use tool 992/10100 to hold the spool, remove circlip 13 and 'clapper' 14 . Unscrew spool end 15 and remove spring 17 with cups 16 and 18 . Check for surface contamination on the under side of the seal plates 2 , 8 and 10 . Clean if necessary. Check for the flatness of the seal plate.
If found to be bent - replace with new (any work previously carried out on this valve may have resulted in the bending of the seal plate). 8 Make sure that the chamfer on item 14 faces away from the solenoid, item 6 . 9 Renew lipseal 11 . Make sure the lipseal is not trapped or damaged. 10 Fit lipseal 11 and seal plate 10 to the valve block section. Torque tighten capscrew 5 on completion. Check the operation of the solenoid 6 after assembly by connecting a 12V supply. The spool should be held when it is pushed into the detent position and returned when the supply is disconnected. Run the engine and inspect the valve for external leaks.
Torque Settings Item Nm kgf m lbf ft 1 9.5 0.96 7 5 9.5 0.96 7 15 9.5 0.96 7 9803/3280 Purchased from www.WorkshopManuals.co.uk Issue 1 Section E Hydraulics Section E 50 - 17 50 - 17 50 - 17 Loader Valve - Fixed Flow 50 - 17