JCB — Variable Flow

www.WorkshopManuals.co.uk 9803/3280 Purchased from www.WorkshopManuals.co.uk Issue 1 Section E Hydraulics Section E 60 - 5 60 - 5 Excavator Valve Removal and Replacement Variable Flow ! WARNING Make the machine safe before working underneath it. Park the machine on level ground, lower the arms. Apply the parking brake, put the transmission in neutral and stop the engine. Chock both sides of all four wheels. Disconnect the battery, to prevent the engine being started while you are beneath the machine. GEN-1-2 ! DANGER Hydraulic Pressure Hydraulic fluid at system pressure can injure you.

Before disconnecting or connecting hydraulic hoses, stop the engine and operate the controls to release pressure trapped in the hoses. Make sure the engine cannot be started while the hoses are open. INT-3-1-11/1 Removal 1 Sideshift the carriage to one side as shown (sideshift machines only). Lower the backhoe and loader end to the ground and stop the engine. 2 Operate the valve block levers back and forth to vent residual pressure. 3 Remove the hose guide A (this makes access to the valve block easier). 3 Remove clevis pins B to disconnect the control levers from the valve block spools. 4 Disconnect all hydraulic hoses from the valve block and plug all orifices to prevent ingress of dirt.

Label each hose before disconnecting, this will ensure correct position when refitting. 5 Insert two M10 bolts through the eye end spools (three spools each end) as shown. Make sure the bolt has a retaining nut on each end. When the bolts are in place thread suitable slings around the bolts as shown. ! CAUTION This component is heavy. Do not attempt to remove it unless its weight is held by a sling. Make sure that the sling is attached to a suitable lifting appliance. HYD 2-3/1 7 Remove nuts C and lower the valve block to the ground. Inspection Inspect the resilient mounts for damage, cracking etc. If the mounts are suspect, then replace them with new ones.

Replacement Replacement is a reversal of the removal sequence. Hoses and pipes (when applicable) must be re-connected and phased in same position as removal. Refer to Dismantling and Assembly, Hoses and Pipes. ! WARNING Fine jets of hydraulic fluid at high pressure can penetrate the skin. Do not use your fingers to check for hydraulic fluid leaks. Do not put your face close to suspected leaks. Hold a piece of cardboard close to suspected leaks and then inspect the cardboard for signs of hydraulic fluid. If hydraulic fluid penetrates your skin, get medical help immediately. INT-3-1-10/1 After replacement check the auxiliary relief valve (A.R.V.) pressure settings. Note:

All hydraulic adapters that are installed together with a bonded sealing washer must also have JCB Threadseal applied to the threads of the adapter.