JCB — Precision Control (Servo) to S/N 931159

www.WorkshopManuals.co.uk Removal and Replacement Precision Control (Servo) Disconnect the stabiliser spool control cables 3 as follows: ! DANGER 1 Undo the lock nut 4 . Hydraulic fluid at system pressure can injure you. Before disconnecting or connecting hydraulic hoses, stop the engine and operate the controls to release pressure trapped in the hoses. Make sure the engine cannot be started while the hoses are open. 2 Undo the housing retaining screws 5 and slide the housing down the cable. INT-3-1-11/1 3 Push out the cable connecting pin 6 and disconnect the cable at the spool. Tie the cables out of harms way. Removal Remove the excavator valve as follows:

1 For access remove bolts 7 and tie hose guard 8 out of the way. It is recommended that the valve is removed complete with its mounting plate. The assembly is lowered down and then out from under the rear on the machine. Before commencing make sure that there is sufficient clearance between the machine and the ground. If necessary raise the rear of the machine using the stabilisers. Chock the machine securely, remembering to leave access for removal of the valve assembly. 2 Uncouple electrical connection to the rear horn 9 . 3 Uncouple electrical connection 10 to the hydraclamp solenoid. The illustration is viewed from the bottom.

4 Record the phasing of the pilot hoses 11 connected at the top and bottom of the excavator valve. The hoses should be labelled, if not label each hose before disconnecting, this will ensure correct position when refitting. Disconnect all hydraulic pilot hoses from the valve block and plug all open ends and ports to prevent ingress of dirt. Before proceding, vent the hydraulic pressure as follows: 1 Stop the engine. With the operator seat set in the rear facing position (for backhoe operation), switch the starter to ON without starting the engine. Operate the joystick controls several times to vent the hydraulic pressure from the servo system and backhoe rams.

5 Record the phasing of the service hoses connected at the front of the excavator valve. Label each hose before disconnecting, this will ensure correct position when refitting. Disconnect all the hoses from the valve block and plug all open ends and ports to prevent ingress of dirt. 2 Operate the stabiliser controls several times to vent pressure from the stabiliser rams. 3 Turn the starter switch to the OFF position and remove the key. 6 Disconnect the inlet 13 and tank return 14 hoses from the valve block, plug all open ends and ports to prevent ingress of dirt. ! WARNING Make the machine safe before working underneath it. Park the machine on level ground, lower the arms.

Apply the parking brake, put the transmission in neutral and stop the engine. Chock both sides of all four wheels. 7 Loosen the three mounting plate bolts 15 - DO NOT completely remove the retaining bolts. Disconnect the battery, to prevent the engine being started while you are beneath the machine. GEN-1-2 ! CAUTION This component is heavy. Do not attempt to remove it unless its weight is held by a sling. Make sure that the sling is attached to a suitable lifting appliance. HYD 2-3/1 To avoid damage to the pilot supply valve (shown at A ), remove it as follows: 8 Open the rear window. Remove the access plate in the cab floor above the excavator valve.

Attach a suitable sling to the mounting bracket slinging point, make sure that the weight of the valve is supported by the sling (shown at B ). 1 Carfully tag all the hoses connected at the valve. Record the phasing. Disconnect the hoses. 2 Uncouple the solenoid electrical connector 1 . 9 Remove bolts 15 and lower the valve block to the ground. 3 Undo the two fixing bolts 2 and remove the valve. 10 If the hose adaptors are going to be removed from the valve block, label before removing to ensure replacement in the correct ports. Record the positions of any restrictors. 9803/3280 Purchased from www.WorkshopManuals.co.uk Issue 2* Section E Hydraulics Section E 60 - 7 60 - 7 Excavator Valve