www.WorkshopManuals.co.uk 9803/3280 Purchased from www.WorkshopManuals.co.uk Issue 1 Section E Hydraulics Section E 96 - 1 96 - 1 Smooth Ride System Accumulator Removal and Replacement Removal 1 Park the machine on level ground, lower the loader arms, switch off the engine and chock all four wheels. Release all hydraulic pressure in the accumulator by selecting the SRS ON and operating the loader arm hydraulic lever. ! DANGER Before disconnecting or dismantling the accumulator discharge all gas pressure. Failure to comply can cause rapid discharge of gas and/or hydraulic fluid which can result in death, personal injury and damage to the machine.
Hyd 2-5 2 Discharge the accumulator, refer to Service Procedures, Smooth Ride System - Charging/Discharging the Accumulator. 3 Disconnect hydraulic hose A and plug. 4 Loosen both ‘U’ clamps B and slide the accumulator towards the front of the machine. When clear of the ‘U’ clamps carefully lower and withdraw accumulator. Replacement Replacement is a reverse of removal. 1 Charge the accumulator, refer to Service Procedures, Smooth Ride System - Charging/Discharging the Accumulator. 2 Operate the machines hydraulic system. Check for correct operation and leaks.
3 Replenish the hydraulic system with the recommended hydraulic fluid as required, refer to Section 3 Fluids, Lubricants, Capacities and Specifications. B A B S308290