JCB — Pressure and Flow Test

www.WorkshopManuals.co.uk Powershift Gearbox Pressure and Flow Testing, cont’d Converter Relief (Safety) Valve Pressure The purpose of the torque converter relief valve is to protect the torque converter from excessive oil pressure. Excessive oil pressure can be generated when the transmission oil temperature is below 50°C and/or the engine is run at over 2000 rev/min. In this event the relief valve opens and returns oil directly to the transmission sump, bypassing the torque converter, cooler and clutch lubrication circuits, protecting against damage due to excessive pressure.

For this reason it is essential that the transmission oil is above 50°C and the engine is run between idle and 1000 rev/min when testing the relief valve. Converter Out Pressure/Oil Cooler Flow Rate Note that the converter out pressure and oil cooler flow rate are affected by the torque converter relief valve operation. Before carrying out tests check the operation of the relief valve (see Converter Relief (Safety) Valve Pressure . 1 Stop engine, connect a 0-20 bar (0-300 lbf/in 2 ) pressure gauge and flowmeter into the converter out line as shown at C and K respectively. 1 Connect a 0-20 bar (0-300 lbf/in 2 ) pressure gauge to test point B .

2 Run the engine at 1000 rev/min with transmission in neutral. The pressure gauge indicates the Converter Out Pressure and the flowmeter indicates the Oil Cooler Flow Rate , both readings should be as specified in Technical Data . A high pressure together with low flow could be caused by a blocked oil cooler or internal leakage. 2 Fit a load valve P into the converter out line. ! CAUTION Make sure the load valve is in the OPEN position, (the adjusting knob screwed fully OUT), before starting the following pressure test. Failure to do this could damage the pump. 3 Repeat step 2 , with engine running at 2000 rev/min note gauge readings which should be as shown in Technical Data .

HYD 4-4/1 4 Stop engine, remove test gauges and refit hoses to original position. DO NOT allow the pressure to exceed 8.3 bar (120 lbf/in 2 ) or damage to the converter seals will be caused. Lubrication Pressure 3 Start the engine and run at 1000 rev/min. With the transmission in neutral, slowly screw down the load valve P whilst observing the gauge reading which should rise to the Converter Relief (Safety) Valve setting as specified in Technical Data. Note that the lubrication pressure is affected by the torque converter relief valve operation. Before carrying out tests check the operation of the relief valve (see Converter Relief (Safety) Valve Pressure .

Note that the gauge pressure will fall once the valve has opened. This is normal relief valve operation and does not indicate a fault. If necessary reset the load valve P and perform the test again, watching the pressure gauge carefully. 1 Stop engine, connect a suitable pressure gauge into the return line from the oil cooler to the transmission as shown at J . 2 Start the engine and run at 1000 rev/min. With the transmission in neutral the pressure gauge will indicate the Lubrication Pressure which should be as specified in Technical Data . 4 If the converter relief valve opens at a pressure higher than specified then the valve is faulty.

A low opening pressure indicates a leaking pump to casing seal or a faulty converter relief valve. 3 Repeat step 2 and note gauge readings with engine running at 2000 rev/min. If the pressure is high the oil cooler may be blocked, (see Converter Out Pressure/Oil Cooler Flow Rate ). 5 Stop engine, remove test gauges and load valve. Refit hoses to original position. 4 Stop engine and remove pressure gauge. 9803/3280 Purchased from www.WorkshopManuals.co.uk Issue 1 Section F Transmission Section F 66 - 6 66 - 6 Service Procedures