JCB — Troubleshooting Guide

www.WorkshopManuals.co.uk Powershift Gearbox - 6 speed ShiftMaster Diagnostics - Troubleshooting Guide 3. DLA Drivers The DLA has software 'drivers' (i.e. programs which handle communications) programmed into the unit. There are matching drivers that must also be resident on you PC. 5. IR Drivers Many Laptop PCs have a built in InfraRed (IR) communications port. There is likely to be some resident software to control this port. If this type of port is present, but never used, then try disabling the driver; The update of both these sets of drivers is handled by JCB Service Master. Please refer to the applicable supporting literature. System Properties > Device Manager > Ports > .....

(infrared) 6. Modem Drivers Check that only the correct modems are installed on the machine. 4. PC Power Management Some laptops' Power Management software can disrupt the COM ports. This problem occurs with many other software applications and is not unique to JCB Service Master applications. The following advice is worth bearing in mind. Experience has shown that multi-user PCs often contain many modems, perhaps installed for use other than in the office. If the user experiences communications problems with a ShiftMaster ECU turn OFF the laptops' power management software. Disable any unused modems.

There has been no experience of correctly installed internal modems or PCMCIA cards (modem or network) causing significant problems. Problems may be; (a) Complete failure to establish communications with an ECU. (b) A drop-out of communications (i.e. connects to the ECU and after a while the link fails). (c) Intermittent failure (i.e. seems to disconnect and re- connect at random intervals). 7. Windows XP & Windows NT Please note the ShiftMaster Diagnostics software is NOT designed to run on Windows NT. In addition JCB can not guarantee that this software will be fully functional with the latest versions of Windows (e.g.

WindowsXP) although JCB are continually developing support for different operating systems. Item (a) is probably the most common. To turn OFF the laptops power management open Windows Control Panel (Start > Settings > Control Panel). There will normally be an icon to run that particular laptops' power management software. Turn OFF the power management, close the tool and then close the control panel. 8. Further Assistance If a communication problem persists, then the following contacts may be able to provide further assistance; These power management tools are specific to the laptop. Some may require the PC to be re-booted before the changes take effect. a).

If applicable, try seeking assistance from your Computer Systems Engineer/Technician. b). The first port of call outside your company should be the laptop machine dealer or agent. c). Your next enquiries should be with the laptop machine OEM (Original Equipmemt Manufacturer). If the OEM is unable to assist they will make the relevant enquires on your behalf. If you continue to have a communications problem, note the applicable laptop make and model. Contact JCB Service so that further investigations can be made.. For all enquiries about the ShiftMaster Diagnostics tool please follow your normal channels of enquiry.

This ensures that useful information can filter through to JCB Service personnel at all levels. 9803/3280 Purchased from www.WorkshopManuals.co.uk Issue 1 Section F Transmission Section F 70 - 2 70 - 2 Service Procedures