www.WorkshopManuals.co.uk Assembly (cont'd) 23 Fit selector forks into position. 24 24 Slide selector rods into position, taking care not to dislodge the interlock plunger. Apply JCB Threadlocker and Sealer to selector fork retaining screws H , and tighten to 35 Nm (26 lbf ft). 25 Fit 1st gear selector detent ball and spring at position A . Apply JCB Threadlocker and Sealer to the detent plug 25a , screw in and tighten. J M 23 H H 26 Temporarily fit the 3rd and 4th gear selector detent assembly at position B , do not apply sealant to the plug at this stage. H 27 Check that each gear engages fully, and that the interlock plunger prevents simultaneous engagement of 2 ratios.
H 23 25 28 Remove the 3rd and 4th gear selector detent assembly from position B . Lift the selector rod J to select 4th gear. With 4th gear selected, temporarily lock the rod in in position by screwing in service tool 892/01077 at B . Temporarily fit service tool 892/01078 to the torque converter end of mainshaft M . If the tool is not available a suitable M8 bolt approximately 100 mm long can be used. A 25a B 29 Apply a bead of JCB Multigasket to mating face of casing. Insert 'O' rings Z . Smear grease onto reverser shaft ring seals, and apply JCB HP Grease to bearings prior to fitting output end casing. 29 Z Note:
Make sure that the forward/reverse shaft ring seals are in good condition before fitting output end casing. Z A388010 9803/3280 Purchased from www.WorkshopManuals.co.uk Issue 1 Section F Transmission Section F 112 - 7 112 - 7 Synchro Shuttle Gearbox