JCB — Assembly

www.WorkshopManuals.co.uk Assembly (cont'd) S221201 A Y A X Z X A396640 9803/3280 Purchased from www.WorkshopManuals.co.uk Issue 2* Section F Transmission Section F 112 - 9 112 - 9 Synchro Shuttle Transmission 33 End Float Checking - Forward/Reverse Unit Measure end float of forward/reverse unit shaft which should be 0.01 to 0.16 mm (0.0004 to 0.006 in). Note: Rotate shaft whilst measuring to seat bearings fully. Position pointer of dial test indicator (DTI) on the chamfer of the shaft, not the end face. This will ensure a constant reading is given. The forward/reverse shaft and its associated components are manufactured using a ‘Setright’ system.

Provided components are assembled correctly the end float will be within the limits given above. If there is no float, or too much end float, separate the casings and check that the bearings inner and outer cups are fitted correctly. If the forward/reverse shaft and clutch assemblies have been dismantled check that the assembly has been carried out correctly. * 34 End Float Setting - Mainshaft If the mainshaft, output shaft and/or associated bearings have been renewed, the shaft end float must be reset. a Remove the torque converter housing and position the gearbox to gain access to setting ring A.

b Using service tool 892/01079 tighten the setting ring to 25 Nm (18.4 lbf ft) whilst at the same time rotating the shaft via the output yoke (a gear must be engaged). Do not over tighten the ring. Overtightening will damage the bearings. c Undo the ring a small amount to obtain a shaft end float of 0.03 to 0.08 mm (0.001 to 0.003 in). To measure the endfloat screw in a bolt (or service tool 892/01078) at the threaded hole in the end of the shaft. Set up a DTI with the probe on the chamfer of the shaft. Zero the DTI. Rotate the shaft and at the same time pull up on the bolt, noting the reading on the DTI. Screw the ring in or out until the end float is correct.

d When the correct setting has been obtained, stake the setting ring to the casing as shown at Y (see the note below). Note that once staked the setting ring can not be used again. If the ring is disturbed it must be discarded and a new one used to re-set the end float. Note: If the slots in the setting ring fall close (within zone Z) to the staking position Y, stake at position X instead. In this event the ring must also be folded on one side at position Y, fold on the side furthest away from the slot in the ring. This is important as the ring will otherwise restrict the flow of lubrication oil.