www.WorkshopManuals.co.uk 9803/3280 Purchased from www.WorkshopManuals.co.uk Issue 1 Section 3 Routine Maintenance Section 3 21 - 3 21 - 3 Battery Battery Isolator To disconnect the battery from the machine electrics a battery isolator has been fitted. ! CAUTION Except in an emergency, do not use the battery isolator to switch OFF the engine. Failure to comply may result in damage to the electrical circuits. INT-3-2-13 At the end of a working cycle or if the machine is being left unattended, provided the lights are not required, the battery must be isolated. Before attempting to start the engine or use the machine electrics the battery isolator key must be fitted and switched on.
1 To isolate the battery turn the battery isolator key A in an anti-clockwise direction B and remove. Keep the key in a safe place and available for when the machine is next required. 2 To connect the battery insert the key A and turn in a clockwise direction C. ! CAUTION Before carrying out arc welding on the machine disconnect the battery and alternator to protect the circuits and components. The battery must still be disconnected even if the battery isolator is fitted. INT-3-1-13 B C A A323611