Purchased from www.WorkshopManuals.co.uk Section F Transmission Section F 127 - 10 Powershift Gearbox 127 - 10 Assembly (cont’d) 10 Fit the Torque Converter Housing - Gearboxes with 18 bolt fix only Important Note: Only the specified sealant can be used. The 10c machine MUST NOT be operated for at least 6 hours after sealant has been applied and the converter housing 10c assembled. This is to allow time for the sealant to cure. a Make sure that the front case and torque converter housing (10a) mating faces are clean, dry and undamaged. Apply a 3 mm wide bead of Bondloc B574 sealant to the front casing as shown at A (pump not shown for clarity).
Make sure that sealant is applied between all the port channels as shown. Take extra 10a special care in the area X as sealing is critical in these areas. Be sure not to block galleries with sealant. Fit a new ‘O’ ring 10d to the housing 10a. 10c 10b b Carefully locate the torque converter casing on the front case. Fit new 10.9 grade bolts as follows: M10 bolts 10b (15 off). Note that spacers are fitted under bolts at positions 10 and 14. M8 bolts 10c. (3 off) Progressively torque tighten the bolts in the sequence shown. Note that the bolt at position 1 is re-torqued after tightening the bolt at position 15.