Purchased from www.WorkshopManuals.co.uk Section F Transmission Section F 127 - 12 Powershift Gearbox 127 - 12 Assembly (cont’d) 10 Fit the Torque Converter Housing - Gearboxes with 23 bolt fix only Important Note: Only the specified sealant can be used. The 10a machine MUST NOT be operated for at least 6 hours after sealant has been applied and the converter housing assembled. This is to allow time for the sealant to cure. a Make sure that the front case and torque converter housing (10a) mating faces are clean, dry and undamaged. Apply a 3 mm wide bead of Loctite 509 10d sealant to the front casing as shown at A (pump not shown for clarity).
Make sure that sealant is applied between all the port channels as shown. Take extra special care at positions X as sealing is critical in these areas. Be sure not to block galleries with sealant. Fit a new ‘O’ ring 10d to the housing 10a. b Carefully locate the torque converter casing on the front case. Fit new 10.9 grade bolts (shown at B) as follows: A401250 M10 x 35 mm bolts (21 off). Note that on some . gearboxes spacers are fitted under bolts at positions Y M8 x 25 mm bolt at position 22. M8 x 45 mm bolt at position 23. Progressively torque tighten the bolts in the sequence shown.
Sequence Bolt Position Torque (shown at B) Nm lbf ft 1 - 21 1 - 21 78 57.5 22 - 23 22 - 23 35 - 40 26 - 30 Powershift Gearbox 9803/3280 Issue 2* 9803/3280 Issue 2*