JCB — Steer Mode Valve - Checking Solenoid Operation

www.WorkshopManuals.co.uk 9803/3280 Purchased from www.WorkshopManuals.co.uk Issue 1 Section H Steering Section H 20 - 4 20 - 4 Service Procedures Steer Mode Valve - Checking Solenoid Operation The solenoids operate according to the steer mode that is selected. Mode: Solenoid(s) Energised: 2 Wheel Steer W 4 Wheel Steer X, Z Crab Steer X, Y Operation (energisation) of a solenoid can be easily detected by placing a steel object (e.g. screwdriver blade) close to the outer casing. A magnetic attraction of the steel object towards the solenoid indicates energisation. If a solenoid is not energising carryout the following checks: 1 Check the fuse is intact.

If not, renew and then check that all steer mode solenoid combinations function correctly. 2 If the fuse is intact remove the electrical connector from the malfunctioning solenoid(s) and check that the 12V supply is present across the connector pins. If not, check the supply circuit. 3 Check the solenoid coil resistance which should measure a few ohms (if unsure of the value compare with a known good solenoid). Renew the solenoid if the reading indicates a short circuit (zero ohms) or open circuit (infinate resistance). If a reading somewhere between the two is obtained, reverse the two instrument probes and repeat for a valid check. W Y X Z A396570 W Y X Z A396570