www.WorkshopManuals.co.uk Priority Valve - Standby Pressure Testing 1 Disconnect hose A and install a 0 - 40 bar (0 - 580 lbf/in 2 ) pressure test gauge into the valve port. Position the open end of hose A into a clean container in order to collect any oil drainage. 2 Disconnect hose B from load sensing port adaptor C and blank off. 3 Set the steering to neutral, i.e. do not turn the steering wheel, and start the engine. Gradually increase the engine speed to 1000 rev/min while checking the maximum pressure gauge reading which should be 5.9 to 8.7 bar (86 to 126 lbf/in 2 ) If the pressure is outside the limits try cleaning the priority valve, refer to Priority Valve - Cleaning .
If cleaning the valve does not rectify, check the hydraulic pump flow rate, refer to Section E Main Pump - Flow and Pressure Testing . B If the hydraulic pump flow and pressure tests are satisfactory, then the priority valve must be renewed. C A 9803/3280 Purchased from www.WorkshopManuals.co.uk Issue 1 Section H Steering Section H 20 - 6 20 - 6 Service Procedures