Komatsu PC210-6K — 16.5 IF BATTERY IS DISCHARGED

16, TROUBLESHOOTING 16.5.1 REMOVAL AND INSTALLATION OF BATTERY @ When removing the battery, remove the cable from the ground side first (normally the negative © terminal). If any tool contacts between the positive @ terminal and the e e When installing, connect the ground cable fast. Tightening torque for battery holder: 9.8 - 14.7 chassis, a spark will be caused. This is dangerous. Nm (1.0 - 1.5 kgfm, 7.2 - 10.9 Ibft) 16.5.2 STARTING When Precautions when e@ When ENGINE starting the engine connecting . connecting WITH BOOSTER CABLE with a booster cable, do as follows: and disconnecting booster cable A WARNING the cables, never contact _.

the positive ; INCORRECT ® x © Nc and negative © terminals. e When starting the engine with a booster cable, always wear safety glasses. e Be careful not to let the normal machine and problem machine contact each other. This prevents sparks from generat- ing near the battery which given off by the battery. cause serious injury. @ Make sure that there could ignite the hydrogen If hydrogen is no mistake gas explodes, in the A0067320 gas it could booster cable connections. The final connection is to the revolving frame, but sparks will be generated when this is done, so connect to a place as far as possible from the battery.

(However, avoid connecting the cable to the work is poor.) e equipment, as conduction Use care when removing the cables from the machine that has been started. Do not allow the cable ends to contact each other or the machine, to avoid hydrogen explosion. NOTICE e@ The size of the booster cable and clip should be suitable for the battery size. e@ The battery of the normal machine must be the same capacity as that of the engine to be started. e@ Check the cables and clips for damage @ Make or corrosion. sure that the cables and clips are firmly connected. 2-97