24. SERVICE PROCEDURE 6. Add the specified amount of engine oil through oil filler port ©. Check that the oil level is between H and L on the sight gauge. NOTICE e For details of the oil to use, see “20. USE OF FUEL, COOLANT AND LUBRICANTS ACCORDING TO AMBINET TEMPERATURE”. 7. After replacing hydraulic oil and cleaning or replacing filter element and strainer, bleed air from the circuit according to the following procedure. 5000 interval (H) e@ If the machine is equipped with the hydraulic breaker, be sure to install an additional filter to the return circuit. When the hydraulic breaker is installed, the hydraulic oil deteriorates earlier than in normal bucket digging work.
Therefore, replace the hydraulic oil according to the chart at the right. Replacement e 4000 \ 3000 Replacement interval for hydraulic oil ~ NN 1000 Additional filter 500 0 (When not : using breaker) 20 40 Breaker ratio (X) Hydraulic filter element 60 operating element 80 250 100 When using breaker only) AW35414B 3-71