Doosan G643 LP Engine — Doosan G643 LP Engine User Manual

LP Fuel Components Specification G643(E) Service Manual Chapter 5. Engine Management System (EMS) 142 Components Q’ty Items Specifications G643E G643 LP Fuel System Requirements - - Operating Temperature LPG Composition Requirements -20 °F to 221°F [-29 °C to 105 °C] HD5 / HD10 LPG. Failure to use fuel compliant with HD5 or HD10 standards will void the user warranty.

LP Fuel Filter 1 1 Fuel Filter Micron Size 40 micron LP Fuel Lock-off 1 1 Electrical Resistance 20~25Ω N-2007 LP Regulator For G643E 1 None Fuel Supply Pressure Fuel Inlet Fitting Fuel Outlet Fitting Fuel Supply Temperature at Tank Outlet Primary Pressure Tap Max Flow Coolant Flow to Vaporizer Fuel Outlet Pressure Setpoints Mounting 10 psi to 250 psi (68.95 kPa to 1723.69 kPa) 1/4” NPT Two 3/4” NPT fittings with one plugged and one 1/8” NPT fitting with plug -20 °F to 120 °F [-29 °C to 49 °C] 1/8” NPT with plug 50 lbm/hr LPG > 1.0 gpm/100bhp, equipped with 140 °F (60 °C) thermostat -0.7 ± 0.2 inH2O @ 1.7 lbm/hr LPG (-1.744 ± 0.498 mbar) @ 1.7 lbm/hr LPG) -2.0 ± 0.2 inH2O @ 50 lbm/hr LPG (-4.982 ± 0.498 mbar) @ 50 lbm/hr LPG) Regulator should be installed with centerline of outlet at least 15° below horizontal to permit drainage of any liquid precipitates from LPG fuel.

Diaphragm should be vertically oriented.