G643 EMS (Engine Management System) Overview General Description MI-04 control system provides a complete, fully integrated engine management system for naturally aspirated engines. It provides accurate, reliable, and durable control of spark and air over the service life of the engine in the extreme operating environment found in heavy- duty, under hood, on-engine electronic controls. The SECM monitors the engine through a number of different sensors to ensure optimal performance. Engine speed is monitored by the SECM through a variable reluctance (VR) sensor. Intake manifold air temperature and absolute pressure are monitored with a TMAP sensor.
MI-04 is a drive-by-wire (DBW) system connecting the accelerator pedal to the electronic throttle through the electrical harness; mechanical cables are not used. A throttle position sensor (TPS) monitors throttle position in relation to the accelerator pedal position sensor (APP) command. Even engine coolant temperature and adequate oil pressure are monitored by the SECM Figure 2. G643 LP System The LPG regulator and the mixer operate as an open loop system since no mixture adjustments are made by the SECM. The mixer does have an idle mixture adjustment and a power valve adjustment.
Manifold pressure from the TMAP, rpm from the crank position sensor and throttle position is used by the SECM to calculate load. Feedback from the electronic throttle is provided to the SECM by the throttle position sensors (TPS). G643(E) Service Manual Chapter 5. Engine Management System (EMS) 168