Doosan G643 LP Engine — Doosan G643 LP Engine User Manual

Lack of Power, Slow to Respond / Poor High Speed Performance / Hesitation During Acceleration (cont’d.) Related MIL Faults: EST faults ETC faults ETC spring check TPS faults APP faults Encoder error Delayed Shutdown faults G643(E) Service Manual 239 Chapter 7. Basic Troubleshooting PROBABLE CAUSE CORRECTIVE ACTION Component malfunction Check SECM grounds for cleanliness and secure connection. See SECM wiring diagrams. Check alternator output voltage. Repair if less than 9 volts or more than 16 volts. Check for clogged air filter and clean or replace as required. Check exhaust system for possible restriction. Refer to Chart T-1 on later pages.

Inspect exhaust system for damaged or collapsed pipes. • Inspect muffler for heat distress or possible internal failure. • Check for possible plugged catalytic converter by comparing exhaust system backpressure on each side at engine. Check backpressure by removing Pre-catalyst O2 sensor and measuring backpressure with a gauge. Engine mechanical See Chapter 3 Engine Mechanical System. Check engine valve timing and compression Check engine for correct or worn camshaft.