Cummins — 4021391

Normal Starting Procedure B3.9, B4.5, and B5.9 Industria [...] Page 1-4 Section 1 - Operating Instructions Normal Starting Procedure General Information Do not depress the accelerator pedal or move the accelerator lever from the idle position while cranking the engine. This can result in engine overspeed and severe damage to the engine. WARNING To prevent damage to the starting motor, do not engage the starting motor for more than 30 seconds. Wait 2 minutes between each attempt to start (electrical starting motors only). CAUTION NOTE: Engines equipped with air starting motors require a minimum of 480 kPa [70 psi]. Disengage the driven unit, or if equipped, put the transmission in neutral.

With the accelerator pedal or lever in the idle position, turn the key switch to the ON position, and wait for the WAIT- TO-START lamp to go out; then, turn the key to the START position. If the engine does not start after three attempts, check the fuel supply system. Absence of blue or white exhaust smoke during cranking indicates no fuel is being delivered.