MAN Nutzfahrzeuge Aktiengesellschaft — Control unit EEPROM computer, 1 fault

Test Control unit EEPROM computer, 1 fault Flash code: 3x long, 2x short Fault indication: Fault indicated by steady light at EDC indicator lamp Fault path: Processor 1 in control unit defective Possible cause: Control unit defective, EOL programming not completed (voltage supply interrupted) Effect of fault: Engine is shut down Engine will not start Important: Do not change the control unit if the entries in the fault memory occurred in the following way: 1. Entry made when ignition is switched off. When the ignition is switched on again the fault which caused this entry to be made is cancelled again and therefore has no effect on operation. 2.

Entry after use of MAN-Cats (EOL programming) If this entry in the fault memory was generated through use of MAN-Cats, the engine can no longer be started. In this case do not change the control unit but repeat the previous work with MAN-Cats. Note: If one of these entries in the fault memory occurs together with the entry Main relay (flashcode: 2x long, 5x short) the reason for this is to be sought not in the control unit but in the main relay (power sup- ply to control unit). 51 Test Measurement Corrective measures Power supply No further test necessary – Complete EOL pro- gramming, delete fault code – Replace control unit Control unit