Komatsu — BATTERY

OPERATION COLD WEATHER OPERATION PREPARATION FOR LOW TEMPERATURE If the temperature becomes low, it may be difficult to start the engine, so do as follows. FUEL AND LUBRICANTS Change to fuel and oil with low viscosity for all components. For details of the specified viscosity, see “LUBRICANTS, FUEL AND COOLANT” in Section 3. COOLANT l In climates where the temperature is above -37°C (-34°F) use a coolant mixture that contains 50 percent antifreeze. Antifreeze is essential in any climate. It broadens the operating temperature range by lowering the coolant freezing point and by raising its boiling point.

Do not use more than 50 percent antifreeze in the mixture unless additional freeze protection is required. Never use more than 68 percent antifreeze under any condition. * DCA4 is recommended for use in the engine. Maintain the supplemental coolant additive concentration level between 1 and 2 units of DCA4 per 3.8 I? (1 US gal) of coolant. * * For details of changing the coolant, refer to “COOLING SYSTEM” in Section 3. BATTERY l As ambient temperature drops, battery capacity will drop, and electrolyte may sometimes freeze if battery charge is low. Maintain battery at a charge level of approximately 100% and insulate it against cold temperature so that machine can be easily started.

* Measure specific gravity of fluid and obtain rate of charge from the following conversion table: * When the electrolyte level is low, add distilled water in the morning before work instead of after the day’s work. This is to prevent the fluid from freezing at night. A WARNING! To avoid gas explosions, do not bring fire or sparks near the battery. 2-68