Komatsu — PPC (PROPORTIONAL PRESSURE CONTROL) CIRCUIT

MAINTENANCE HYDRAULIC TANK The hydraulic tank and system should be bleed free of air after the following: l Replacing the hydraulic oil and filter elements or cleaning the oil strainer. l Removing a hydraulic component or disconnecting hydraulic piping. After reassembly, bleed the air from the hydraulic tank and system as follows: 1. Check and if necessary refill the hydraulic tank with oil up to the specified oil level of the sight gauge. NOTICE: Check the hydraulic tank oil level and refill with oil frequently when bleeding the system.

* At first, if the engine is operated at high speed or if the hydraulic cylinder is moved to the end of its stroke, the air in the cylinder may damage the cylinder piston packing, etc. 2. Run the engine at low idle. One at a time, operate the hydraulic steering, bucket and lift arm cylinders four (4) to five (5) times, stopping 100 mm (3.9 in) from the end of its full stroke. 3. Next, operate each hydraulic cylinder three (3) to four (4) times, to the end of its stroke, then stop the engine. 4. Loosen the two air bleed plugs (1) on the hydraulic tank to bleed the air. After bleeding the air, tighten the two air bleed plugs. 5. Recheck the hydraulic tank oil level and add oil as necessary. 6.

Start the engine, increase the engine speed and repeat Steps 3 and 4 to bleed the air until no more bubbles come out from the bleed plug ports. 7. After bleeding the air, tighten the two air bleed plugs (1). * Tightening torque of bleed plug: 1.15 f 0.15 kgm (8.3 + 1 .O Ibf ft / 11.3 + 1.4 Nom) 8. Recheck the oil level in the hydraulic tank and add oil as necessary. After adding oil, tighten the oil filler cap securely. PPC (PROPORTIONAL PRESSURE CONTROL) CIRCUIT The PPC, proportional pressure control, circuit should be bleed free of air after the following: l Cleaning the PPC circuit hydraulic oil strainer. l Removing or disconnecting hydraulic piping of the PPC circuit.

After reassembly, bleed the air from within the pressure control circuit as follows: 1. Check and if necessary refill the hydraulic tank with oil up to the specified oil level of the sight gauge. 3-31