Komatsu — SYSTEM COMPONENTS

OM4200 Automatic Lubrication System - Section 42 Page 42-3 SYSTEM COMPONENTS Vent Valve (6, Figure 42-1) With the vent valve closed, the pump continues to operate until maximum grease pressure is achieved. As this occurs, the vent valve opens and allows the grease pressure to drop to 0, so the injectors can recharge for their next output cycle. Filter (21, Figure 42-2) A filter assembly mounted on the grease reservoir fil- ters the grease prior to refilling the reservoir from the shop supply. A bypass indicator alerts service per- sonnel when the filter requires replacement.

Hydraulic Motor and Pump (3 & 8, Figure 42-1) Lubrication Cycle Timer (1, Figure 42-4) The rotary hydraulic pump is a fully hydraulically operated grease pump. An integrated pump control manifold is incorporated with the motor to control input flow and pressure. The solid state lubrication cycle timer provides a 24 VDC timed-interval signal to energize the solenoid valve (5, Figure 42-1), providing oil flow to operate the grease pump motor. This timer is mounted in the Electrical Interface Cabinet. Note: The pump crankcase oil level must be maintained to the level of the pipe plug port. If necessary, refill with 10W-30 motor oil.

Delay Timer (11, Figure 42-4) The delay timer, located in the Electrical Interface Cabinet, provides a one minute delay in the low pres- sure warning lamp circuit to allow a normally operat- ing system to attain full grease system pressure without activating the warning lamp. If the system fails to reach 2000 psi (13 789 kPa) within this time period, the timer will apply 24VDC to several relays which will illuminate the low pressure warning lamp in the overhead display. An external 604K ohm resistor determines the delay period. Hydraulic oil supply inlet pressure must not exceed 3000 psi (20 685 kPa).

Exceeding the rated pressure may result in damage to the sys- tem components and personal injury. Pump Cutoff Pressure Switch (N.O. 2500 psi [17 237 kPa]) (10, Figure 42-1) Grease Reservoir (12, Figure 42-1) This pressure switch de-energizes the pump sole- noid relay when the grease line pressure reaches the switch pressure setting, turning off the motor and pump. The reservoir has an approximate capacity of 60 lbs. (27 kg) of grease. When the grease supply is replen- ished by filling the system at the service center, the grease is passed through the filter to remove con- taminants before it flows into the reservoir. Grease Pressure Failure Switch (N.O.

2000 psi [13 789 kPa]) (9, Figure 42-2) Pressure Reducing Valve (4, Figure 42-1) The pressure reducing valve, located on the manifold reduces the hydraulic supply pressure (from the truck steering circuit) to a suitable operating pressure, [325-350 psi (2 240-2 415 kPa)] for the hydraulic motor used to drive the lubricant pump. This pressure switch monitors grease pressure in the injector bank on the rear axle housing. If the proper pressure is not sensed within 60 seconds (switch contacts do not close), several relays energize, actu- ating a warning lamp circuit to notify the operator a problem exists in the lube system.

Flow Control Valve (9, Figure 42-1) Pressure Gauge (7, Figure 42-1) The flow control valve mounted on the manifold, con- trols the amount of oil flow to the hydraulic motor. The flow control valve has been factory adjusted and the setting should not be disturbed. The pressure gauge monitors hydraulic oil pressure to the inlet of the hydraulic motor. Injectors (24, Figure 42-2) Each injector delivers a controlled amount of pres- surized lubricant to a designated lube point. Refer to Figure 42-2 for locations. Solenoid Valve (5, Figure 42-1) The solenoid valve, when energized, allows oil to flow to the hydraulic motor.