Komatsu — 1000 Hour Inspection

Automatic Lubrication System - Section 42 OM4200 Page 42-14 PREVENTATIVE MAINTENANCE PROCEDURES The following maintenance procedures should be used to insure proper system operation. 4. Inspect all bearing points for a bead of lubricant around the bearing seal. Daily Lubrication System Inspection It is good practice to manually lube each bearing point at the grease fitting provided on each Injector. This will indicate if there are any frozen or plugged bearings, and will help flush the bearings of contami- nants. 1. Check grease reservoir level. Inspect grease level height after each shift of operation. Grease usage should be consistent from day-to-day operations. 5.

System Checkout Lack of lubricant usage would indicate an inoperative system. Excessive usage would indicate a broken supply line. 2. Check filter bypass indicator when filling reser- voir. Replace element if bypassing. a. Remove all SL-1 injector cover caps to allow visual inspection of the injector cycle indicator pins during system operation. b. Start truck engine. 3. Check all grease feed line hoses from the SL-1 Injectors to the lubrication points. c. Actuate the lube system test switch. The hydraulic motor and grease pump should operate. a. Repair or replace all damaged feed line hoses. d. With the grease under pressure, check each SL-1 injector assembly.

The cycle indicator pin should be retracted inside the injector body. b. Make sure that all air is purged and all new feed line hoses are filled with grease before sending the truck back into service. 4. Inspect key lubrication points for a bead of lubri- cant around seal. If a lubrication point appears dry, troubleshoot and repair problem. e. When the system attains 2500 psi (17 237 kPa), the pump should shut off and the pressure in the system should drop to zero, venting back to the grease reservoir. 250 Hour Inspection f. With the system vented, check all of the SL-1 injector indicator pins; all of the pins should be visible. Replace or repair injec- tors, if defective. 1.

Check all grease feed line hoses from the SL-1 Injectors to the lubrication points (see, Figure 42-1). a. Repair or replace all worn / broken feed line hoses. g. Reinstall all injector cover caps. h. Check timer operation. b. Make sure that all air is purged and all new feed line hoses are filled with grease before sending the truck back into service. Note: With engine running, lube system should activate within 5 minutes. The system should build 2000 to 2500 psi within 25-40 seconds. 2. Check all grease supply line hoses from the pump to the SL-1 injectors. a. Repair or replace all worn / broken supply lines. i. If the system is working properly, the truck is ready for operation. b.

Make sure that all air is purged and all new supply line hoses are filled with grease before sending the truck back into service. j. If the system is malfunctioning, refer to the troubleshooting chart. 3. Check grease reservoir level. a. Fill reservoir if low. b. Check reservoir for contaminants. Clean, if required. 1000 Hour Inspection Check pump housing oil level and correct if neces- sary. c. Check that all filler plugs, covers and breather vents on the reservoir are intact and free of contaminants.