OM3038 8/03 Operating Instructions - Section 30 Page 30-11 2. Place rest switch in ON position to put AC Drive system in "rest" mode of operation. Be sure the "rest" indica- tor light in the overhead panel is illuminated. 3. With engine cooled down, turn keyswitch counterclockwise to OFF position for normal shutdown of engine. If engine does not shutdown with keyswitch, use engine shutdown switch on operator cab center console, and hold this switch down until engine stops. 4. With keyswitch OFF, and engine stopped, wait at least 90 seconds. Insure steering circuit is completely bled down by turning steering wheel back and forth several times.
No front wheel movement will occur when hydraulic pressure is relieved. If the vehicle continues to steer after shutdown, notify maintenance personnel. 5. Verify all link voltage lights are off (one on back interior wall of operator cab, two on electrical cabinet, on deck), and notify maintenance personnel if remains illuminated longer than five minutes after the engine is shut down. 6. Close and lock all windows, remove key from keyswitch and lock cab to prevent possible unauthorized truck operation. Dismount truck properly. Put wheel chocks in place. DELAYED ENGINE SHUTDOWN PROCEDURE 1.
Stop the truck out of the way of other traffic on a level surface and free of overhead power lines or other obstructions (in case dump body should need to be raised). a. Reduce engine speed to low idle. b. Place the selector switch in NEUTRAL. c. Apply the parking brake switch. Be sure the parking brake applied indicator light in the overhead display panel is illuminated. 2. Place rest switch in ON position to put AC Drive System in "rest" mode of operation. Be sure the "rest" indica- tor light in the overhead panel is illuminated. 3. Refer to Instrument Panel and Indicator Lights in this section for location of the engine shutdown switch with 5 minute idle timer delay.
This is a 3-position rocker-type switch (OFF-ON-MOMENTARY). 4. Press the top of the engine shutdown switch to select the ON (center) position. Press the top of the switch again to activate the timer delay (MOMENTARY position). Release the switch and allow it to return to the ON position. When the engine shutdown timer has been activated, the timer delay indicator light in the overhead status panel will illuminate to indicate that the shutdown timing sequence has started. The engine will continue to idle for approximately 5 minutes to allow for proper engine cool-down before stopping. 5.
Turn the keyswitch counterclockwise to the OFF position to cause the engine to shutdown when the timing sequence is complete. When the engine stops, this will activate the hydraulic bleeddown timer and turn off the 24 VDC electric circuits controlled by the keyswitch. NOTE: To cancel the 5 minute idle timer sequence, press the timer delay shutdown switch to the OFF (lower) position. If the keyswitch is in the OFF position, the engine will stop. If the keyswitch is in the ON position, the engine will continue to run. e h e e e s r own when the timing