TROUBLESHOOTING OPERATION ELECTRONIC CONTROL SYSTEM If an error code appears on the machine monitor display (normally displays TIME), follow the countermeasure table as shown below in the self-diagnosis. Machine monitor failure display Monitor display Failure mode Remedy PC-EPC valve system error If the pump override switch is set to the ON position, opera- tion can be carried out, however, have the PC-EPC valve system inspected by your Komatsu distributor. (*) E02 Set the swing override switch to the On position to release the brake. If applying swing brake, manually operate swing lock switch. In this case, have the swing brake system inspection immediately by your Komatsu distributor.
(*) E03 Swing brake system error The governor cannot carry out control. Operate the gover- nor lever manually. To secure at the full position, there is a mounting hole for the lock bolts in the bracket. In this case, carry out inspection immediately by your Komatsu distribu- tor. E05 Governor system error CALL Operation cannot be continued Place the machine to a safe posture, and carry out inspec- tion immediately by your Komatsu distributor. IN case where the monitor will not display no error code and work equipment or swing opera- tion cannot be carried out. Carry out inspection immediately.
(*) For detail of operating the pump override switch and the swing override switch, see “SWITCHES on page 66. I 152