MAINTENANCE ! SERVICE PROCEDURE Pure washer fluid comes in two types: for -10°C (for general use) and for -30°C (cold regions). Use pure washer fluid according to operation area and season. CHECK, MAINTAIN AIR CONDITIONER CHECK LEVEL OF REFRIGERANT (GAS) A WARNING If the refrigerant used in the cooler gets into your eyes or on your hands, it may cause loss of sight or frostbite, so never loosen any part of the refrigerant circuit. If the level of the refrigerant (gas) is low, the cooling effect will be reduced.
Run the engine at high idling, and check the flow of the refrigerant gas (freon 134a) in the refrigerant circuit through the sight glass of the receiver when the cooler is running at high speed. o (A) No bubbles in refrigerant flow: Suitable I I o (B) Some bubbles in flow (bubbles pass continuously): Lack of refrigerant o (C) Colorless, transparent: No refrigerant REMARK When there are bubbles, the refrigerant gas level is low, so contact your refrigerant dealer to have refrigerant added. If the air conditioner is run with the refrigerant gas level low, it will cause damage to the compressor.
INSPECTION DURING OFF-SEASON Even during the off-season, run the compressor at low speed for 3 - 5 minutes once a month to prevent the loss of the oil film at the lubricated Parts of the compressor. Inspection and maintenance items list for cooler .. L Refrigerant (gas) Charge amount Twice a year (spring, autumn) Condenser I Clogged fins I Every 500 hours Compressor Every 4000 hours Operating condition i V-belt Damage, tension Every 250 hours I ~ 189