Komatsu — EVERY 250 HOURS SERVICE

SERVICE PROCEDURE MAINTENANCE LUBRICATE SWING CIRCLE (2 POINTS) 1. Lower the work equipment to the ground. 2. Using a grease gun, pump in grease through the grease fit- tings shown by arrows. 3. After greasing, wipe off all the old grease that was pushed out. CHECK AIR CONDITIONER COMPRESSOR BELT TENSION ADJUST. CHECKING 1. Remove belt guard (1 ) 2. Press compressor drive belt midway between fan pulley and compressor pulley. The belt should normally deflect by about 15 - 18 mm when pressed with the finger (with a force of approx. 6 kg ADJUSTING 1. Loosen two nuts and bolts (1) 2. Carefully lever compressor housing as shown to tighten belt to within tightness criteria.

Tighten lower bolt to hold in posi- tion. 3. Tighten upper bolt. 200