Komatsu — EVERY 500 HOURS SERVICE

MAINTENANCE SERVICE 5. Install a new element in the place where old element (4) was installed. 6. Set valve (3) and spring (2) on top of the element. 7. Set cover (1) in position, push it down by hand, and install the I I cover with the mounting bolts. 8. Screw in the oil filler cap and install the cover. To bleed the air, start the engine according to “STARTING ENGINE” on page 102 and run the engine at low idling for 10 minutes. 4000 ~L 9. Stop the engine. eliminate bubbles in the oil inside the tank. Operate the machine after halting for more than 5 minutes to REMARK for hydraulic oil IO.

Check for oil leakage and wipe off any spilled oil 2000 When the hydraulic breaker is installed, the hydraulic oil deterio- rates earlier than in normal bucket digging work. The first element replacement should be at 100 to 150 hours for new machines. Thereafter, replace the element according to the table on the right. 20 40 60 80 100 Breaker operating (When using ratio(%) breaker only) Hydraulic filter element AD31373D O I 207 . .