MACHINES READY FOR ATTACHMENTS OPTIONS, ATTACHMENTS I 5. Turn the rotor of the stop valve connected to the inlet and out- let piping on the arm side face to the free position. 6. Confirm that oil level in the hydraulic oil tank is correct, after mounting the attachment. I FLOW STOP OPERATION A WARNING Be careful when operating the pedal in the deceleration range. The engine speed will rise suddenly. Do not put your foot on the pedal except when operating the pedal. If rest your foot on the pedal during opera- tions, and it is depressed by accident, the attachment may move suddenly and cause serious damage or injury. Operate the attachment as follows.
WHEN USING BREAKER Set the stop valve to the FLOW position, and depress the front of the pedal to operate the breaker. C Select the working mode for breaker (B.0). Precautions when using I Check that the stop valve is in the FLOW position. Check that the selector valve is in the position for using the breaker. For details of the path followed by the oil, see “5. HYDRAULIC CIRCUIT” on page 241. For details of other precautions when handling the breaker, read and use correctly the instruction manual provided by the breaker manufacturer.
When using the breaker, the hydraulic oil deteriorates more rapidly than for normal operations, so change the hydraulic oil and replace the element at a shorter interval. For details, see “MAINTENANCE WHEN USING HYDRAU- LIC BREAKER” on page 212. 244