Komatsu — CHECK BEFORE STARTING ENGINE

OPERATION OPERATION ~ CHECK AIR CLEANER FOR CLOGGING 1. Confirm that the air cleaner clogging monitor does not flash 2. If it flashes, immediately clean or replace the element. For details of the method of cleaning the element, see MENT” on page 178. “CHECK, CLEAN AND REPLACE AIR CLEANER ELE- CHECK ELECTRIC WIRINGS AD313590A A WARNING 0 If the fuse blows frequently, or there are traces of short- circuiting in the electric wiring, always locate and repair the cause. 0 Accumulation of flammable material (dead leaves, twigs, grass etc.) around the battery may cause fire, so always check and remove such material.

0 Keep the top surface of the battery clean and check the breather hole in the battery cap. If it is clogged with dirt or dust, wash the battery cap to clear the breather hole. Check for damage and wrong capacity of the fuse and any sign of disconnection or short circuit in the electric wiring. Check also for loose terminals and tighten any loose parts. Check the wiring of the “battery”, “starting motor” and “alternator” carefully in particular. When carrying out walk-around checks or checks before starting, always check if there is any accumulation of flammable material around the battery, and remove such flammable material.

Please contact your Komatsu distributor for investigation and cor- rection of the cause. CHECK FUNCTION OF HORN 1. Turn the starting switch to the ON position. 2. Confirm that the horn sounds without delay when the horn button is pressed. If the horn does not sound, ask your Komatsu distributor for repair. 96