. MAINTENANCE MAINTENANCE PROCEDURE MAINTENANCE MAINTENANCE PROCEDURE 3) Remove 1 seal from the element whenever the element has been cleaned. 4 - 23 8. If small hole s or thinner parts ar e found on the element when it is checked the element. by shining a light th rough it after cle aning , replace 9. Remove the cloth or tape coveri ng inne r eleme nt (6). NOTICE lement whose folds or gasket or seal are damaged. Do not use an e lement whose folds o r gasket or seal a re damaged. If the element or O-ring are cleaned a nd used again aft er they have b een used for more than 1 year, it will cause proble ms. Do not use them ag ain. 10.
Check that t here is no dirt or oil stuck to the se al portion of the new element or c leaned element. Wipe off any dirt or oil. er element in straight with your hand when installing it to the air cleaner body. 11. Push the out er element in straig ht with your ha nd when installing it to the air cle If the outer e element can lement is held and r ocked l ightly up and down and to the left and rig ht while pushing i t in, th e outer be inserted easily. NOTICE he air cleaner element facing in the correct direction.
Be sure to install t he air cleaner element facing i n the cor rect direction Install so that the b ottom of the air cleane r eleme nt cylinde r (face where no hole is drilled) (B), (C) is at cover (3) end . If the direction of installatio n is mistaken, there is danger that it will c ause breakage of the air cleaner e. leaner element or serious damage to the engin