. MAINTENANCE MAINTENANCE PROCEDURE stopper, then remove it. 4 - 29 1. Stop the machine on level ground, then stop the engine. 2. 3. Check that the cooling w ater temperature has gone d own 4. enough to make it possible to touch the radiator cap surfac e by hand, then turn radiator c stopper to release the pres Following this, push radiato ap (2) slowly until it contacts the sure. r cap (2), turn it until it contacts the 5. Remove the undercover, t hen set the container under drain nt mixture. rain valve (3) to catch the coola Open drain valve (3) at the bottom of the radiator and drain the coolant. 6. After draining the coolant, c lose drain valve (3), and fill with city water.
When the radiator is full, start the engine and run at law idle to raise the temperat ure to at least 90°C (194°F), then mately. 10 minutes. drain valve (3) to drain the water. ean the radiator with detergent. ollow the instruction of detergent. then continue to run for approxi 7. Stop the engine and open drain valve (3) to drain the wat 8. After draining the water, cl ean the radiator with detergent For the cleaning method, f ollow the instruction of deterge 9. Close drain valve (3). Install the undercover. 10. 11. Add coolant through the wa ter filler port up to the mouth o f the port. For details of the C DENSITY TABLE". OOLANT density, see "COOLANT 12.
Run the engine at law idle f or 5 minutes to remove the air f rom the water, then run at high i dling for 5 minutes. (Leave radiator cap (2) removed when doi ng this.)