Komatsu — 24.10.5 LUBRICATE

MAINTENANCE 24.10.4 REPLACE IN-LINE FUEL STRAINER 1. Close the shut off valve under the fuel tank. 2. Loosen the clamps holding the hose to the strainer at both ends and remove the strainer. 3. Install the new strainer with the arrow pointing in the direction of flow (away from the fuel tank). Open the fuel shut off valve. 24.10.5 LUBRICATE Mounted Equipment Controls REMARK Five fittings without a ripper or six fittings with a ripper. Apply grease until clean lubricant is visible. Always use a clean lubricator and wipe dirt from fittings before fresh grease is applied. If grease fails to go through the fitting, determine the cause and correct it.

After greasing, wipe off any old grease that was purged. Left and Right Foot Pedals Apply grease until clean lubricant is visible. Always use a clean lubricator and wipe dirt from fittings before fresh grease is applied. If grease fails to go through the fitting, determine the cause and correct it. After greasing, wipe off any old grease that was purged. Undetfloor Linkage Apply grease until clean lubricant is visible. Always use a clean lubricator and wipe dirt from fittings before fresh grease is applied. If grease fails to go through the fitting, determine the cause and correct it. After greasing, wipe off any old grease that was purged. 3-56