Assembly Procedure PC8000 28. Filling up hydraulic tank Z22959 ) Connect all lines of the refilling arm* ( hydraulic oil; fuel; grease). * if so equipped For capacity’s and further information refer to the Maintenance Manual. Filling up hydraulic oil Fill up hydraulic oil to the maximum level. Be sure the main shut off valve (10) is open. Do it via the service arm below the engine house or direct through the refilling plug of the hydraulic tank if so equipped. Use only hydraulic oil according to the Maintenance Manual. Observe the oil level with the hydraulic tank level gauge. Filling up via service arm:

Connect hydraulic oil supply line from service truck / station to the filling adapter on the central refilling panel of the swing down service arm. Filling up via refilling plug: Open the refilling plug. Fill up the hydraulic oil. The new oil flows through the return oil filter into the main tank. During filling up observe the filter chamber oil level through the refilling plug. It can be overflow because of the filter flow resistance. Remove air from the hydraulic system: ѓ Open vent plugs (12) on the pump suction ports of all eight main pumps (11) and on the four gear type pumps (16). As soon as bubble free oil flows out tighten the vent plugs (12).

ѓ Open the vent plugs on top of both axial piston pumps (15). As soon as bubble free oil flows out tighten the vent plugs on both axial piston pumps (15). Check oil level in the eight main pump housings: ѓ Remove oil level and filler plug (13). The oil level in the pump housing should reach the lower edge of the opening. The port (14) of the leakage oil return line can also be used for checking and filling of the pump housing. ѓ If necessary add hydraulic oil up to the lower edge of the filler opening. ѓ Insert and tighten filler plug (13) respectively connect leakage oil return line to port (14).

ѓ Make sure the main pump housings are correctly filled, other-wise the pump drive shaft bearings could be damaged due to lack of lubrication. Final checks: Check hydraulic oil level and check the complete system for leak-age; especially the connection between main oil and suction oil reservoir. Make sure the main shut-off valve is completely open. PC8000AS rev 02.doc 121 Edition 01/2004