Komatsu PC8000AS — PC8000AS rev 02

Assembly Procedure PC8000 33. Assembling and testing the Fire Detection, Actuation and Suppression System The excavator is equipped with two different systems: A – Checkfire MP-N electric detection and actuation system which controls the Carbon Dioxide fire suppression system for the following areas: - Slip ring unit; - High voltage switch cabinet; - Medium and low voltage switch cabinet in the cab base. B – Checkfire SC-N electric detection and warning system which monitors the machinery house via a linear detection wire. A – Checkfire MP-N electric detection and actuation system Z23009 – Principle representation of the pneumatic actuation system 1.

Strike button at the power house door for manual actuation 2. Strike button in the operators cab for manual actuation 3. Automatic actuator controlled by thermal detectors 4. Pressure switch shuts off the main motors depend on the activators (1; 2; 3) 5. Steel cylinder filled with extinguishing gas Carbon Dioxide (cab base). 6. Hose from the strike button at the power house to the cab base. 7. Hose from the operators cab to the cab base. A; B Connection points in the cab base below the floor. Z23010 - Principle representation of the extinguishing gas Carbon Dioxide system 1. Second hose at the gas steel cylinder in the cab base. 2.

Extinguishing gas pour out nozzle nearby the gas steel cylinder. 3. Extinguishing gas pour out nozzle below the floor in the cab base. 4. Extinguishing gas pour out nozzle at the overhead wall in the cab base. 5. Steel cylinder filled with extinguishing gas Carbon Dioxide (cab base). 6. Extinguishing gas pour out nozzles in the high voltage cabinet. 7. Extinguishing gas pour out nozzle at slip ring. ) All necessary parts are packed in a separate box. PC8000AS rev 02.doc 145 Edition 01/2004