Komatsu — 24.2.5 CHECK ELECTRICAL INTAKE AIR HEATER

MAINTENANCE When Increasing Tension Prepare a grease gun. 1. Pump in grease through grease fitting (2) with a grease gun. 2. To check that the tension is correct, move the machine slowly forward and backward. 3. Check the track tension again, and if the tension is not correct, adjust it again. NOTE If the track adjustment cannot be attained, it is permissible to pump in grease until S becomes 0 mm. If the tension is still loose, the pin and bushing are excessively worn, so they must be either turned or replaced. Please contact your distributor. When Loosening Tension WARNING It is extremely dangerous to release the grease by any method except the procedure given below.

If the track tension is not relieved by this procedure, please contact your distributor. 1. Loosen plug (1) gradually to release the grease. 2. Turn plug (1) a maximum of one turn. 3. If the grease does not come out smoothly, move the machine backwards and forwards a short distance. 4. Tighten plug (1). 5. To check that the correct tension has been achieved, move the machine backwards and forwards. 6. Check the track tension again, and if the tension is not correct, adjust it again. 24.2.5 CHECK ELECTRICAL INTAKE AIR HEATER Before the start of the cold season (once a year), contact your distributor to have the electrical intake air heater repaired or checked for dirt or disconnections. 3-33