4.7.2. Cleaning of the cooling inside system circuit When the cooling system circuits are fouled with water scales or sludge particles, the cooling efficiency will be lowered. When the cooling system circuits are clogged, the water pump mechanical seal is damaged. The poor condition of the cooling system is normally due to use of unsuitable or no anti-freezing agents and corrosion inhibitor or defect.
If twice in a short time (within 6 months) the water pump of an engine develops leases or the coolant is heavily contaminated (dull, brown, mechanically contaminated, gray or black sings of a leakage on the water pump casing) clean the cooling system prior to removing that water pump as follows. a) Drain coolant. b) Remove thermostats, so that the whole cooling system is immediately flown through when cleaned. c) Fill the cooling system with a mixture of potable water and 1.5% by volume of cleaner. (Henkel P3T5175) d) Warm up engine under load. After a temperature of 60 ° C is reached, run engine for a further 15 minutes. e) Drain cleaning fluid. f) Repeat steps c) and d).
g) Fill cooling system with hot water. h) Run engine at idle for 30 minutes. At the same time continuously replenish the water leaking from the bore in drain plug by adding fresh water. CAUTION : Periodically clean the circuit interior with a cleaner. DL06 Diesel Engine Commissioning and Operation 167