Doosan DL06 — Doosan DL06 User Manual

z Inspection and correction (1) With steel rule and feeler gauge, measure the axial end play of the oil pump gear. Replace if the measured value is beyond the limit. Steel plate Feeler gauge (2) With a feeler gauge, measure the amount of backlash between the oil pump drive gear and driven gear. Replace if the measured value is beyond the limit. (3) Measuring clearance between drive shaft and bushing a. Measure the outside diameters of the drive shaft and driven shaft, and replace if the measured values are less than the limit. b.

Measure the inside diameter of the pump body bushing to determine the clearance between the bushing and shaft, and compare the measured value with the standard value to determine whether to replace or no. z Reassembly (1) For reassembly, reverse the disassembly sequence. DL06 Diesel Engine Maintenance of Major Components 173 End play limit 0.03 ∼ 0.136 mm Standard 0.312 ~ 0.476 mm Limit 0.64 mm Standard φ21.936 ∼ φ21.95 mm Limit φ21.90 mm Oil clearance 0.050 ~ 0.085 mm