Doosan DL06 — Doosan DL06 User Manual

DL06 Diesel Engine Special Tool List 202 Group Part Inspection item Stand value for assembly Limit for use Correction Remark Water pump Delivery volume l/min - Pump speed 2,500rpm - Water temp.

80°C - Back pressure 0.5 kg/cm2 200 or more Check the water passage For any Restrictions - Diameter of water pump shaft Pulley side φ25.048~φ25.0 - 61 Impeller side φ16.045~φ16.0 - 56 Clearance of bearing 0.050~0.091 Clearance between impeller & housing 0.4 ~ 0.8 - Replace if impeller & housing are damaged Squareness of pulley 0.1 - Fan belt depression Refer to adjust - Adjust table Cooling water temp Operating temperature (permissible temp.) (°C) 82 ~ 95 - Must not exceed this value Permissible temperature in a short time (°C) - 105 Thermo stat Thermostat opening temperature °C (under atmospheric pressure) 82 - Replace Full opening temperature (°C) 95 - Replace if defective Stroke : min.

8mm Fuel system Fuel high pressure pump maker (CP pump) Bosch - Common rail maker Fuel injector maker Piping & others Fuel pipe, injection pipe & nozzle holder for damage, cracks, improper O-ring - - Replace Fuel filter cartridge for damage - - Replace cartridge Injection pressure of injector (kg/cm2) Max 1,600 - Operating pressure of overflow valve (kg/cm2) 10.5 ~13 - Replace valve Diameter of injector nozzle 8 - φ0.136 Projection height of nozzle from the cylinder head surface(mm) 3.0 - Use sealing by option Air compre ssor Air compre ssor Inner diameter of cylinder B grade φ90.000~φ90.0 - Replace same grade 10 C grade φ90.010~φ90.0 - 20 D grade φ90.020~φ90.0 - 30 Diameter of piston B grade φ89.910~φ89.9 - Replace same grade 20 C grade φ89.920~φ89.9 - 30